Agilent / Inficon 3000A micro GC 4ch with 3 detectors, control laptop PC with EZIQ
Web Information
The 3000 Micro GC Gas Analyzer is a powerful GC solution that provides fast, accurate, reliable analysis of your gas sample on-line, right at the sampling point. It is ideal for the rapid analysis of gas streams in alternative energy, coal mine safety, and the hydrocarbon processing industry, which includes refineries, natural gas production and distribution, chemical operations, and oil and gas exploration. Its rugged construction ensures long-term, trouble-free operation. And with its modular design, reconfiguration and repair can be easily and quickly accomplished by interchanging Micro GC modules, keeping you in control of your gas analysis and your process.
The Portable 3000 Micro GC truly mobilizes gas chromatograph analysis. Simply carry this portable GC to your sampling point, run the analysis and collect the desired measurement data. Our EZ IQ™ software is both feature rich and user friendly, allowing even a non-chromatographer to control the instrument and accomplish GC operation with ease.
Condition
Seller refurbished. Unit is fully functional. This is a 4 channel unit with 3 detectors installed. Detectors where checked for gas leaks and single run test methods executed to check for detector functionality. New CMOS battery installed.
System Configuration:
GC Type: 2801
Instrument serial number: US10611002
Module 1: Channel Assignment: A Part Number: G2801-60501 Serial Number: US00608025 Board Serial Number: STI060661180 Sample Inlet: Heater ID: m0:ThermA Pressure Sensor ID: NONE Injector: Type: Backflush Part Number: G2801-60760 Serial Number: 0022-25C Description: ID Backflush 1.0ul Heater ID: m1:ThermC Column: Type: Molsieve Part Number: G2801-61104 Serial Number: US5412426H-2 Description: 10m MS-5A 12um Film Thickness: 12.00 µm Inside Diameter: 320.00 µm Length: 10 m Temperature Limits: Lower: 30 °C Upper: 180 °C Detector: Type: TCD Part Number: G2801-60630 Serial Number: 0012-09-P06 Description: Assy Detector (TCD) Signal Description: TCD2 A Pre-Column: Type: PLOTU Part Number: Serial Number: Description: 3m PPU 30um Film Thickness: 30.00 µm Inside Diameter: 320.00 µm Length: 3 m Temperature Limits: Lower: 30 °C Upper: 180 °C Sample Pump ID: m0:Pump0 Gas Supply: Type: Ar Location: carrier1 |
Module 2: Channel Assignment: B Part Number: G2801-60501 Serial Number: US00610002 Board Serial Number: STI060661179 Sample Inlet: Heater ID: m0:ThermA Pressure Sensor ID: NONE Injector: Type: Backflush Part Number: G2801-60760 Serial Number: 0027-24D Description: ID Backflush 1.0ul Heater ID: m2:ThermC Column: Type: Molsieve Part Number: G2801-61104 Serial Number: US6459314H-3 Description: 10m MS-5A 12um Film Thickness: 12.00 µm Inside Diameter: 320.00 µm Length: 10 m Temperature Limits: Lower: 30 °C Upper: 180 °C Detector: Type: TCD Part Number: G2801-60630 Serial Number: 0012-09-Q13 Description: Assy Detector (TCD) Signal Description: TCD2 A Pre-Column: Type: PLOTU Part Number: Serial Number: Description: 3m PPU 30um Film Thickness: 30.00 µm Inside Diameter: 320.00 µm Length: 3 m Temperature Limits: Lower: 30 °C Upper: 180 °C Sample Pump ID: m0:Pump1 Gas Supply: Type: Ar Location: carrier2 |
Module 3: Channel Assignment: C Part Number: G2801-60502 Serial Number: US00609004 Board Serial Number: STI060661185 Sample Inlet: Heater ID: m0:ThermC Pressure Sensor ID: NONE Injector: Type: Backflush Part Number: G2801-60760 Serial Number: 0035-17E Description: ID Backflush 1.0ul Heater ID: m3:ThermC Column: Type: PLOTU Part Number: G2801-61105 Serial Number: US5454626H-1 Description: 8m PPU 30um Film Thickness: 30.00 µm Inside Diameter: 320.00 µm Length: 8 m Temperature Limits: Lower: 30 °C Upper: 160 °C Detector: Type: TCD Part Number: G2801-60630 Serial Number: 0012-06-L13 Description: Assy Detector (TCD) Signal Description: TCD2 A Pre-Column: Type: PLOTQ Part Number: Serial Number: Description: 1m PPQ 10um Film Thickness: 10.00 µm Inside Diameter: 320.00 µm Length: 1 m Temperature Limits: Lower: 30 °C Upper: 160 °C Sample Pump ID: m0:Pump1 Gas Supply: Type: Ar Location: carrier2 |
Includes
- Agilent / Inficon 3000A micro GC unit with 3 detectors installed
- Genie gas sample filter model 170
- Panasonic Toughbook CF-74 with EZIQ software installed
- Power cables
Warranty
30 Day warranty. We pledge to offer the best service and warranty to all of our customers! We are extending a 30 Day warranty on this item. This is our way of saying thank you for allowing us to serve you.
Certification
This is a genuine product from this manufacturer.