Dionex DX-120 Ion Chromatograph w/ AS40 Automated Sampler & Chromeleon 6.5 PC
Web Information
The Dionex DX-120 Ion Chromatograph performs isocratic ion analysis applications using conductivity detection. The DX-120 is an integrated system, which includes a pump, detector, and injection valve. The chromatography components, including the column(s), Self-Regenerating Suppressor (SRS ), and conductivity cell are
ordered separately. These components are mounted on the inside of
the DX-120 door. The DX-120 can be controlled locally, using the front panel keypad
and display, or remotely, from a PeakNet/Chromeleon workstation. The PeakNet or Chromelon workstation consists of a computer with a LAN interface card and PeakNet software (Release 4.30 or higher) or Chromeleon installed. Limited remote control is also available using TTL signals.
The DX-120 can be ordered as a single-column system or a dual-column system. The dual-column system allows switching between two sets of columns (column select mode) or between two eluents (eluent select mode). In the eluent select mode, the DX-120 can perform step gradients.
Specification | |
Operating Temperature | 10°C to 40°C (50°F to 104°F) |
Operating Humidity | 59% to 95% relative humidity, noncondensing |
Decibel level | 53 db (at A Weighing setting) |
Gas Pressure | Laboratory-quality helium, regulated to between 0.14 and0.69 MPa (20 and 100 psi) |
Operating Pressure | 28 MPa (4000 psi) maximum liquid path (tubing, valves,columns, etc.) |
Type | Single-reciprocating piston with metal-free flow path with PEEK components |
Operation Mode | Constant volume |
Flow Range | 0.5 to 4.5 mL/min |
Maximum Pressure | 28 MPa (4000 psi) |
Range | 1000 µS, full-scale |
Temperature Compensation | 1.5, 1.7, or 1.9% per ºC |
Cell Drive | Pulsed, bipolar fixed frequency |
Auto Offset | -999 to 999 µS |
Local Operation | Front panel controls and display status of all functions |
Remote Operation | Control of four functions via TTL inputs |
Condition
Used. Removed from working environment due to lab closure.
Includes
- Dionex DX-120 Ion Chromatograph
- AS40 Automated sampler
- Dell Windows XP SP3 control computer with Chromeleon 6.5 SP3 with Hardware dongle
- Original software license activation paperwork
- Centrecom MR420TR Network interface switch
- DS4 Detection stabilizer DS4-1
- Thermo DRS ADRS 600 4mm
- Chromeleon 6.5 Manuals
- Power cables, network cables
Warranty
30 Day warranty. We pledge to offer the best service and warranty to all of our customers! We are extending a 30 Day warranty on this item. This is our way of saying thank you for allowing us to serve you.
Certification
This is a genuine product from this manufacturer.
Disclaimer
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item."
Regardless of the origin of the equipment, documentation provided or identification appearing upon the equipment, the equipment described and offered here is in no way certified for, recommended for, or offered for any specific use. The purchaser agrees that the seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment. The purchaser, by bidding on this equipment, indicates their acknowledgment of, and agreement to the terms of this disclaimer. it is the purchaser's responsibility to have the item inspected and certified by a qualified professional before use!