HACH 2100N Laboratory Turbidimeter 47000-60, Unit #3, calibrated

Hach

$639.00 
SKU: Hach2100N

Sorry, this item is out of stock

Web Information

Accuracy: ± 2 % of reading plus 0.01 NTU from 0 - 1000 NTU
±5% of reading from 1000 - 4000 NTU
Air Purge: 0.1 scfm at 69 kPa , hose barb connection for 1/8 in tubing, maximum 138 kPa. Dry nitrogen or instrument-grade air.
Compliance Certifications: UL/CSA
Dimensions (H x W x D): 156 mm x 400 mm x 305 mm
Display Type: 8-digit LED display
Interface: RS232 serial (bi-directional)
Lamp Type: Tungsten
Manual Languages: English, Spanish, French, German
Max. operating humidity: 90 %
Measurement Modes: NTU, EBC, Nephelo
Operating Temperature Range: 0 - 40 °C
Power Options: 115 V AC with US power cord
Power Requirements: 115 - 230 VAC; 50 to 60 Hz; 60 VA maximum
Range: 0 - 4000 NTU
  0 to 0.999 EBC units, EBC mode, ratio on: manual
  0 to 26800 Nephelos, Nephelo mode, ratio on: auto, auto-decimal
  0 to 26800 Nephelos, Nephelo mode, ratio on: manual
  0 to 268 Nephelos, Nephelo mode, ratio off
  0 to 40.0 NTU, NTU mode, ratio off
  0 to 4000 NTU, NTU mode, ratio on: auto, auto decimal
  0 to 4000 NTU, NTU mode, ratio on: manual
  0 to 9.8 EBC units, EBC mode, ratio off
  0 to 9.99 EBC units, EBC mode, ratio on: manual
  0 to 9.99 Nephelos, Nephelo mode, ratio on: manual
  0 to 9.99 NTU, NTU mode, ratio on: manual
  0 to 980 EBC units, EBC mode, ratio on: auto, auto-decimal
  0 to 980 EBC units, EBC mode, ratio on: manual
  0 to 99.9 EBC units, EBC mode, ratio on: manual
  0 to 99.9 Nephelos, Nephelo mode, ratio on: manual
  0 to 99.9 NTU, NTU mode, ratio on: manual
  Ratio On: Manual 0 - 10000 ; Auto 0 - 10,000 auto decimal; Ratio Off: 0 - 40.0
Regulatory: USEPA method 180.1
Repeatability: ± 1 % of reading or ± 0.01 NTU, whichever is greater
Response Time: 6.8 s with signal averaging off; 14 s with signal averaging on
Sample Cell Compatibility: 25 mm round; 12, 13, 16, and 19 mm round with optional adapter kit
Sample Volume: 30 mL with 25 mm sample cells
Serial input interface: RS232 serial interface (bidirectional)
Source Lamp: Tungsten lamp
Stabilization Time: 30 min with ratio on
Stabilization time: 60 min with ratio off
Storage Conditions: -40 °C to 60 °C
User Interface: Button
User Interface Languages: English

Condition

Used. Excellent working condition!  We performed calibration with the Hach calibration standards kit.  (please note:  Calibration standards are not included in the sale)

Includes

    • HACH 2100N Laboratory Turbidimeter 47000-60
    • Power cord

    BBR1

        Warranty

        30 Day warranty. We pledge to offer the best service and warranty to all of our customers!  We are extending a 30 Day warranty on this item. This is our way of saying thank you for allowing us to serve you

        Certification

        This is a genuine product from this manufacturer.

        Disclaimer:

        Regardless of the origin of the equipment, documentation provided or identification appearing upon the equipment, the equipment described and offered here is in no way certified for, recommended for, or offered for any specific use. The purchaser agrees that the seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment. The purchaser, by bidding on this equipment, indicates their acknowledgment of, and agreement to the terms of this disclaimer. it is the purchaser's responsibility to have the item inspected and certified by a qualified professional before use.!!