HP Agilent 1100 HPLC G1376A Cap Pump
Web Information
Hydraulic System |
Two dual piston in series, with proprietary servo-controlled variable stroke drive, floating piston, active inlet valve, solvent selection valve and electronic flow control for flow rates up to 100 µl/min |
Settable Column Flow Range |
0.01 – 20 µl/min 0.01 – 100 µl/min (with the extended flow range kit) 0.001 – 2.5 µl/min (with the electronic flow control bypassed) |
Recommended Column Flow Range |
1 – 20 µl/min 10 – 100 µl/min (with extended flow range kit) 0.1 – 2.5 ml/min (with the electronic flow sensor bypassed) |
Column Flow Precision |
< 0.7 % RSD or 0.03 % SD (typically 0.4 % RSD or 0.02 % SD), at 10 µl/min and 50 µl/min column flow (based on RT, default setting) |
Optimum Composition Range |
1 to 99% or 5 µl/min per channel (primary flow), whatever is greater |
Composition Precision |
< 0.2 % SD, at 10 µl/min (20 µl flow sensor), 50 µl/min (100 µl flow sensor) and 1 ml/min (normal mode) default setting |
Delay Volume |
Typically 3 µl from the electronic flow control to the pump outlet for flow rates up to 20 µl/min. Typically 12 µl from the electronic flow control to the pump outlet for flow rates up to 100 µl. for flow rates up to 100 µl/min and electronic flow control active: primary flow path 180 - 480 µl without mixer, 600 - 900 µl with mixer (system pressure dependant) Typically 180 to 480 µl (system pressure dependent) without mixer for flow rates up to 2.5 ml/min. (Mixer delay volume 420 µl) |
Pressure Range |
20 to 400 bar (5880 psi) system pressure |
Compressibility Compensation |
User-selectable, based on mobile phase compressibility |
Recommended pH Range |
1.0 – 8.5, solvents with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries. |
Control and Data Evaluation |
Agilent ChemStation for LC |
Analog Output |
For pressure monitoring, 2 mV/bar, one output |
Communications |
Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional |
Safety and Maintenance |
Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. |
GLP Features |
Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of seal wear and volume of pumped mobile phase with user-settable limits and feedback messages. Electronic records of maintenance and errors. |
Housing |
All materials recyclable. |
Condition
Seller refurbished. Instrument is in excellent functional condition. Passed all built in self tests. Unit was removed in current configuration from a working environment.
Includes
- HP Agilent 1100 HPLC G1376A Cap Pump
- power cord
Warranty
30 Day warranty. We pledge to offer the best service and warranty to all of our customers! We are extending a 30 Day warranty on this item. This is our way of saying thank you for allowing us to serve you.
Certification
This is a genuine product from this manufacturer.